Shear in structural member

The section of a structural member may be subjected to shear force due to flexure, punching or torsion. Accordingly, the shear may be flexural shear, punching shear or torsional shear. Flexural shear: The shear associated with change of bending moment along the span is known as flexural shear. The beams are usually subjected to flexural shear. For beams, the flexural shear is commonly referred as ‘shear’. Punching shear: The shear associated with the possibility of punching a thin member by a concentrated wall load, a beam-less floor slab supported directly…

Read More

SUBMISSION DRAWING – 01

submission drawing

To understand the submission drawing, it is very important to first understand some of its basic requirements. Therefore, in this drawing, only some basic things have been explained to you. This submission drawing is very simple, which will give you a basic idea of how and on which the submission is actually made. If you understand this, then you can make a submission drawing of any building yourself. A submission/Passing drawing must contains the following items; All Floor Plans Minimum one Section Minimum one elevation Site plan Key Plan North…

Read More

TATA Projects Recruitment

Job Role: Technical Lead/Project Lead Job Description: Experienced and highly skilled candidate having required work experience in complex refinery, petrochemical and Oil & Gas projects. He /She will be reviewing, coordinating &will be front facing with client and engineering consultants to ensure seamless work delivery with quality and on schedule with value engineering. Qualification: Bachelor of Engineering (BE) or higher degree in Civil Engineering from an accredited university. Skills : Staad Pro/ ETABS Pre Bid quantification and estimation Detail Engineering Team Management Value Engineering Statutory compliance in layout and plant…

Read More

Floor Space Index

Means the quotient of the ratio of the combined gross built-up area of all floors, to the total area of the Building-unit (total plot area including common plot). Floor Space Index = Total Built-up area of all floors / Area of the Building – unit Permissible FSI – Means the basic FSI permitted by the Competent Authority as a matter of right. Base FSI – Means the base FSI permitted in a Base Zone by the Competent Authority as a matter of right. Chargeable FSI – Means the FSI available…

Read More

Fire Protection and Life Safety

All definitions mentioned under these title are mutatis and mutandis with the Fire Prevention and Life Safety Measurement Act-2013, Rules-2014 and Regulations-2016 made their under and amended from time to time. Automatic Sprinkler System means an arrangement of pipes and sprinklers, automatically operated by heat and discharging water on fire, simultaneously an audible alarm. Combustible Material means that material which when burnt adds heat to a fire when tested for combustibility in a accordance with the IS : 3808-1966 Method of Test for Combustibility of Building Material, National Building Code.…

Read More